Title:Reliability and agreement of digital caliper and ultrasound measurements for inter-recti distance in postpartum women
Authors:ID Weingerl, Iva (Author)
ID Šarabon, Nejc (Author)
ID Kozinc, Žiga (Author)
Files:.pdf RAZ_Weingerl_Iva_2026.pdf (10,26 MB)
MD5: 90FB0A053B0C2FA1DE1D5128125610DB
 
URL https://www.mdpi.com/2076-3417/16/17/8705
 
Language:English
Work type:Article
Typology:1.01 - Original Scientific Article
Organization:FVZ - Faculty of Health Sciences
Abstract:Diastasis Recti Abdominis is a common postpartum condition characterized by separation of the rectus abdominis muscles. Accurate measurement of inter-recti distance (IRD) is important for diagnosis and longitudinal monitoring, but the extent to which digital caliper and ultrasound measurements agree across abdominal sites remains uncertain. This study examined between-visit test–retest reliability within each method, caliper–ultrasound agreement, and associations with palpation at 4.5 cm above the umbilicus, at the umbilicus, and 4.5 cm below the umbilicus. Thirty healthy primiparous women 8–16 weeks after vaginal delivery completed two visits three days apart. Test–retest reliability was good to excellent (absolute-agreement ICC = 0.83–0.98; TE = 0.09–0.25 cm; CV = 2.84–8.28%; MDC = 0.24–0.70 cm). Caliper–ultrasound agreement varied by site and visit (absolute-agreement ICC = 0.72–0.95; TE = 0.12–0.30 cm; CV = 3.89–9.91%). Lin’s concordance correlation coefficient (CCC) ranged from 0.72 to 0.95, and inter-method minimal detectable change percentages (MDC%) ranged from 10.8% to 27.5%. Caliper values were systematically lower than ultrasound values above the umbilicus by 0.081 cm at Visit 1 and 0.068 cm at Visit 2 (both p = 0.031), while the widest limits of agreement occurred at the umbilicus and below the umbilicus at Visit 1. Visit 1 correlations between palpation and instrument-based measurements were moderate to very strong (Spearman’s ρ = 0.641–0.920). Thus, each instrument was sufficiently stable for repeated assessment under this protocol, but cross-method disagreement was site-dependent, and the data did not permit a definitive judgment of clinical interchangeability without a validated acceptability threshold. Using the same method across follow-up assessments is therefore recommended.
Keywords:pregnancy, abdominal wall, exercise
Publication version:Version of Record
Publication date:01.09.2026
Year of publishing:2026
Number of pages:str. 1-14
Numbering:Vol. 16, iss. 17, [article no.] 8705
PID:20.500.12556/RUP-23994 This link opens in a new window
UDC:618.2
ISSN on article:2076-3417
DOI:10.3390/app16178705 This link opens in a new window
COBISS.SI-ID:289863939 This link opens in a new window
Publication date in RUP:03.11.2026
Views:208
Downloads:18
Metadata:XML DC-XML DC-RDF
:
Copy citation
  
Average score:(0 votes)
Your score:Voting is allowed only for logged in users.
Share:Bookmark and Share

Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Record is a part of a journal

Title:Applied sciences
Shortened title:Appl. sci.
Publisher:MDPI
ISSN:2076-3417
COBISS.SI-ID:522979353 This link opens in a new window

Document is financed by a project

Funder:Other - Other funder or multiple funders
Project number:P5–0443
Name:Kinesiology for the effectiveness and prevention of musculoskeletal injuries in sport
Acronym:KINSPO

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Secondary language

Language:Slovenian
Abstract:Diastaza premih trebušnih mišic je pogosto stanje po porodu, za katerega je značilna povečana razdalja med premima trebušnima mišicama. Natančno merjenje razdalje med premima trebušnima mišicama (IRD) je pomembno za diagnostiko in spremljanje sprememb skozi čas, vendar stopnja skladnosti med meritvami z digitalnim kljunastim merilom in ultrazvokom na različnih mestih trebušne stene še ni povsem pojasnjena. Namen raziskave je bil proučiti zanesljivost ponovljenih meritev med obiskoma za vsako metodo posebej, skladnost med meritvami z digitalnim kljunastim merilom in ultrazvokom ter povezanost teh meritev s palpacijo na treh mestih: 4,5 cm nad popkom, v višini popka in 4,5 cm pod popkom. V raziskavi je sodelovalo 30 zdravih prvorodnic, 8–16 tednov po vaginalnem porodu, ki so opravile dva obiska v razmiku treh dni. Zanesljivost ponovljenih meritev je bila dobra do odlična (ICC za absolutno skladnost = 0,83–0,98; TE = 0,09–0,25 cm; CV = 2,84–8,28 %; MDC = 0,24–0,70 cm). Skladnost med digitalnim kljunastim merilom in ultrazvokom se je razlikovala glede na mesto meritve in obisk (ICC za absolutno skladnost = 0,72–0,95; TE = 0,12–0,30 cm; CV = 3,89–9,91 %). Linov koeficient skladnosti (CCC) je znašal od 0,72 do 0,95, medmetodne vrednosti MDC% pa od 10,8 % do 27,5 %. Nad popkom so bile vrednosti, izmerjene z digitalnim kljunastim merilom, sistematično nižje od ultrazvočnih meritev, in sicer za 0,081 cm ob prvem in 0,068 cm ob drugem obisku (v obeh primerih p = 0,031). Najširše meje skladnosti so bile ugotovljene v višini popka in pod popkom ob prvem obisku. Ob prvem obisku so bile korelacije med palpacijo in meritvami z instrumentoma zmerne do zelo močne (Spearmanov ρ = 0,641–0,920). Rezultati kažejo, da sta bili obe metodi pri ponovljenih meritvah v okviru uporabljenega protokola dovolj stabilni, vendar je bila medmetodna skladnost odvisna od mesta meritve. Na podlagi pridobljenih podatkov brez vnaprej določenega in validiranega praga sprejemljivega odstopanja ni mogoče dokončno presoditi o klinični medsebojni zamenljivosti metod. Zato je pri spremljanju skozi čas priporočljivo uporabljati isto merilno metodo.
Keywords:nosečnice, trebušna stena, vadba


Comments

Leave comment

You must log in to leave a comment.

Comments (0)
0 - 0 / 0
 
There are no comments!

Back
Logos of partners University of Maribor University of Ljubljana University of Primorska University of Nova Gorica