Lupa

Izpis gradiva Pomoč

A- | A+ | Natisni
Naslov:Reliability of novel postural sway task test
Avtorji:ID Sedliak, Milan (Avtor)
ID Cvecka, Jan (Avtor)
ID Tirpáková, Veronika (Avtor)
ID Loefler, Stefan (Avtor)
ID Šarabon, Nejc (Avtor)
ID Kern, Helmut (Avtor)
ID Hamar, Dušan (Avtor)
Datoteke:URL http://www.bio.unipd.it/bam/PDF/23-3/Sedliak.pdf
 
Jezik:Angleški jezik
Vrsta gradiva:Delo ni kategorizirano
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:IAM - Inštitut Andrej Marušič
Opis:The purpose of this study was to examine the reliability of parameters obtained from a novel postural sway task test based on body movements controlled by visual feedback. Fifty-nine volunteers were divided into two groups. The first group consisted of young (n = 32, 16 females and 16 males, age: 25.2 3.4 years) and the second group of elderly individuals (n = 27, 17 females and 10 males, age: 75.7 6.9 years). Participants stood in parallel on a computer based stabilographic platform with the feet approximately a shoulder width apart, the toes slightly pointing outwards, the hands placed on the hips. The computer screen was placed approximately 1.5 meter from the platform at a height of subjects eyes. An instantaneous visual feedback of participants centre of pressure (COP) was given in a form of a blue cross visible on the screen. Participants were instructed to keep the blue cross driven by movements of their hips as close as possible to a predefined curve flowing on the screen. Out of the 6 parameters studied, only the average distance of COP from the curve line and the sum of the COP crossings through the curve line showed high reliability. Correlation between these two highly reliable parameters was -0.89. There was also a statistical difference (p<0.001) between young and elderly in both the average distance of COP from the curve line and the sum of the COP crossings through the curve. To conclude, the novel postural sway task provides a simple tool with relatively low time burden needed for testing. The suggested output parameters measured are highly reliable and easy to interpret
Ključne besede:balance, postural control, task test, visual feedback
Leto izida:2013
Št. strani:str. 81-84
Številčenje:23, 3
PID:20.500.12556/RUP-423 Povezava se odpre v novem oknu
ISSN:2037-7460
UDK:796.012.266
COBISS.SI-ID:2390483 Povezava se odpre v novem oknu
Datum objave v RUP:15.10.2013
Število ogledov:4307
Število prenosov:248
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Komentarji

Dodaj komentar

Za komentiranje se morate prijaviti.

Komentarji (0)
0 - 0 / 0
 
Ni komentarjev!

Nazaj
Logotipi partnerjev Univerza v Mariboru Univerza v Ljubljani Univerza na Primorskem Univerza v Novi Gorici