Lupa

Izpis gradiva Pomoč

A- | A+ | Natisni
Naslov:Test–retest reliability of postural sway measures using a portable low-cost force plate in healthy adults
Avtorji:ID Vindiš, Miha (Avtor)
ID Kozinc, Žiga (Avtor)
ID Nedović, Nenad (Avtor)
Datoteke:URL https://onlinelibrary.wiley.com/doi/10.1002/pri.70270
 
URL https://doi.org/10.1002/pri.70270
 
.pdf RAZ_Vindis_Miha_2026.pdf (550,07 KB)
MD5: 3819BC0F3D6D93E845133D217DB76FCD
 
Jezik:Angleški jezik
Vrsta gradiva:Članek v reviji
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:FVZ - Fakulteta za vede o zdravju
Opis:Background and Purpose Center of pressure (CoP) metrics derived from force plates are widely used to quantify postural control, but laboratory-grade systems limit routine clinical and field implementation. Portable low-cost force plates could enable physiotherapists to monitor balance longitudinally, provided that their measurements are sufficiently reliable and clinically interpretable. This study addresses a gap in the literature by systematically comparing the test–retest reliability of CoP outcomes across bipedal and single-leg stance conditions using a portable low-cost force plate, providing device-specific and task-specific validation data relevant to clinical and field-based implementation. Methods This test–retest reliability study included 27 healthy young adults who completed two laboratory sessions 7–10 days apart. In each session, participants performed three 30-s trials of bipedal quiet stance and three 30-s trials of single-leg stance on each leg barefoot with standardized arm position and visual fixation. Mean values across repetitions were analyzed. Relative reliability was assessed using two-way mixed-effects ICC for absolute agreement (3,1), with 95% confidence intervals. Absolute reliability was quantified using typical error (TE) and coefficient of variation (CV). Paired t-tests evaluated systematic between-session differences. Results Across all outcomes, single-leg stance demonstrated substantially higher inter-session reliability compared to bipedal stance. Measures of total CoP displacement and velocity during single-leg stance exhibited good to excellent reliability (ICC = 0.85–0.90) and low absolute error (CV ≈ 8%), with direction-specific displacements showing similarly consistent results (ICC = 0.83–0.90; CV generally < 10%). In contrast, the CoP ellipse area and standard deviation measures were considerably less stable (ICC = 0.57–0.79) and displayed markedly higher variability (CV ≈ 16%–23%). The contrast was even more pronounced in the bipedal stance, where reliability was poor to moderate across all parameters (ICC = 0.39–0.65), with the ellipse area exhibiting excessive variability (CV > 60%). Notably, no systematic between-session differences were observed for most outcomes, further supporting the consistency of the measurements. Discussion In healthy young adults, single-leg stance provides more reliable CoP measures than bipedal quiet stance when using a portable low-cost force plate. Displacement- and velocity-based outcomes during single-leg stance appear most suitable for repeated assessments and monitoring. MDC95 values should be interpreted strictly as measurement-error thresholds and not as indicators of clinical responsiveness or meaningful clinical change because responsiveness was not evaluated.
Ključne besede:balance, reliability, force plate
Verzija publikacije:Objavljena publikacija
Datum objave:02.07.2026
Leto izida:2026
Št. strani:str. 1-9
Številčenje:Vol. 31, iss. 3, [article no.] e70270
PID:20.500.12556/RUP-23287 Povezava se odpre v novem oknu
UDK:612.76
ISSN pri članku:1471-2865
DOI:10.1002/pri.70270 Povezava se odpre v novem oknu
COBISS.SI-ID:284112387 Povezava se odpre v novem oknu
Datum objave v RUP:08.07.2026
Število ogledov:41
Število prenosov:0
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Skupna ocena:(0 glasov)
Vaša ocena:Ocenjevanje je dovoljeno samo prijavljenim uporabnikom.
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Physiotherapy research international
Skrajšan naslov:Physiother. res. int.
Založnik:Whurr Publishers
ISSN:1471-2865
COBISS.SI-ID:517808409 Povezava se odpre v novem oknu

Gradivo je financirano iz projekta

Financer:ARIS - Javna agencija za znanstvenoraziskovalno in inovacijsko dejavnost Republike Slovenije
Številka projekta:P5-0443
Naslov:Kineziologija za učinkovitost in preventivo mišično-skeletnih poškodb v športu

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Naslov:Test-retest zanesljivost mer posturalnega nihanja z uporabo prenosne nizkocenovne pritiskovne plošče pri zdravih odraslih
Ključne besede:ravnotežje, ponovljivost, plošče za merjenje sil


Komentarji

Dodaj komentar

Za komentiranje se morate prijaviti.

Komentarji (0)
0 - 0 / 0
 
Ni komentarjev!

Nazaj
Logotipi partnerjev Univerza v Mariboru Univerza v Ljubljani Univerza na Primorskem Univerza v Novi Gorici